Building Permits at 541 Royal St [galerie Dart Francais], New Orleans, LA


Estimated Price

Beds

Baths

Rooms

Sq.Ft.

Built:   Lot size:   Taxed:
RENOVATION HISTORY
Based on the information received from building department, associated with 541 Royal St [galerie Dart Francais], New Orleans, LA over the past .

If you are considering hiring for your home renovation project, we recommend using our bidding system to get competitive quotes.

ACTIVITY



PERMITS VALUATION



RENOVATIONS
Find out the best time of the year to complete your project on a minimal budget.
Get several free quotes from best contractors in your area.

REQUEST A QUOTE
Explore CheckPermit
Our dataset includes 30 milion building permits across 4 million addresses in US.

We analyzed and ranked over 1 million home remodeling contractors based on official government sources.

Every contractor's rank is calculated based on official government records.
RECENT PROJECTS


Content Date Cost Contractor Rank Address Contractor
To repair stuccoed masonry as needed to match existing on second-story of both royal & toulouse elevations using the following vcc approved mortar & stucco formula:mortar: no more than 1 part portland cement, 3 parts lime, 9 parts sand, and enough water to form a workable mix. Prepackaged mixes are not permitted, as quality control is not consistent. Stucco: base coat consists of 2 coats, doubled up work of 5/8" total thickness. Proportioned as follows: no greater than 1:12 part portland cement, to 3 parts lime, and 9 parts sand, 6 lbs./cubic yard hair or fiber, and enough water to form a workable mix. Finish coat is 1/4" in total thickness proportioned as follows: no more than 1 part portland cement, 3 parts lime, 9 parts sand, enough water to form a workable mix. Note: ratio of portland cement not to exceed 1:12. 2016. 04. 05 - permit not picked up.
Date:  June 4, 2014

Permit type: Vcc general work | Permit status: Permit expired due to ina | Completion date: April 5, 2016 | Expiration date: December 5, 2014 | Current use: Business use | Permit id: 14-17601-Vcgen
2014/06/04095541 Royal St [galerie Dart Francais], New Orleans, La
Replace and paint shutters, paint gallery railing, paint exterior stucco.
Date:  January 23, 2015

Permit type: Vcc paint | Permit status: Permit issued | Expiration date: July 26, 2015 | Current use: Business use | Permit id: 15-02392-Vcpnt
2015/01/23095541 Royal St [galerie Dart Francais], New Orleans, La
Proposal to remove ornamental outriggers and install new angled struts under existing balcony to reinforce balcony and remove sag.
Date:  March 5, 2015

Permit type: Vcc general work | Permit status: Voided - applicant withdr | Completion date: March 18, 2015 | Current use: Business use | Permit id: 15-06185-Vcgen
2015/03/05095541 Royal St [galerie Dart Francais], New Orleans, La
This is a renewal of vcc permit #11-0535to do the following work as necessary: remove deteriorated floor boards, stringers, and fascia boards install new 3"x4" beaded stringers, 5/4x4 s2s t&g floorboards, and 7/8" fascia with " bead, all as per vcc standard detail sheet no. 18 (attached) all repair/replacement work shall match existing in color, size, material, detail, profile and exposure prime & paint to match existing color (off-white)
Date:  August 8, 2012

Permit type: Vcc general work | Permit status: Permit expired | Completion date: November 26, 2014 | Expiration date: February 8, 2013 | Current use: Business use | Permit id: 12-21504-Vcgen
2012/08/08095541 Royal St [galerie Dart Francais], New Orleans, La
Repair masonry cracks as needed with vcc approved mortar/stucco mix, using 1 part portland cement, 3 parts lime, 9 parts sand, enough water to form a workable mix repair ground floor millwork including faade vitrine, to match existing conditions repair/replace as necessary doors & shutters on the 2nd & 3rd floors street elevations, with the removal of the existing plywood in the openings which is currently in the windows/doors of both floors will be removed all repair work shall match existing in color, size, material, detail, profile and exposure to prepare for painting by washing using a low water pressure; sanding (rotary sanders cannot be used); making minor millwork and/or masonry repairs as necessary to match existing conditions (masonry mix must be soft with portland cement content not to exceed 1 part to 12); and to paint as follows to match existing:o wallsbay gray, flat or satin finisho wooden elements including doors, windows, frames, fascia/soffit of gallerywhite, semigloss
Date:  March 27, 2013

Permit type: Vcc general work | Permit status: Permit expired | Completion date: November 11, 2014 | Expiration date: September 27, 2013 | Current use: Business use | Permit id: 13-09412-Vcgen
2013/03/27095541 Royal St [galerie Dart Francais], New Orleans, La
Renewal of permit # 13-09412 to perform the following work: repair masonry cracks as needed with vcc approved mortar/stucco mix, using 1 part portland cement, 3 parts lime, 9 parts sand, enough water to form a workable mix repair ground floor millwork including faade vitrine, to match existing conditions repair/replace as necessary doors & shutters on the 2nd & 3rd floors street elevations, with the removal of the existing plywood in the openings which is currently in the windows/doors of both floors will be removed all repair work shall match existing in color, size, material, detail, profile and exposure to prepare for painting by washing using a low water pressure; sanding (rotary sanders cannot be used); making minor millwork and/or masonry repairs as necessary to match existing conditions (masonry mix must be soft with portland cement content not to exceed 1 part to 12); and to paint as follows to match existing:o wallsbay gray, flat or satin finisho wooden elements including door
Date:  February 14, 2014

Permit type: Vcc general work | Permit status: Permit issued | Expiration date: August 17, 2014 | Current use: Business use | Permit id: 14-05170-Vcgen
2014/02/14095541 Royal St [galerie Dart Francais], New Orleans, La
Repair masonry cracks as needed with vcc approved mortar stucco mix, using 1 part portland cement, 3 parts lime, 9 parts sand, enough water to form a workable mix repair ground floor millwork including faade vitrine, to match existing conditions repair replace as necessary doors & shutters on the 2nd & 3rd floors street elevations, with the removal of the existing plywood in the openings which is currently in the windows doors of both floors will be removed all repair work shall match existing in color, size, material, detail, profile and exposure to prepare for painting by washing using a low water pressure; sanding (rotary sanders cannot be used); making minor millwork and or masonry repairs as necessary to match existing conditions (masonry mix must be soft with portland cement content not to exceed 1 part to 12); and to paint as follows to match existing:o wallsbay gray, flat or satin finisho wooden elements including doors, windows, frames, fascia soffit of gallerywhite, semigloss
Date:  March 27, 2013

Permit type: Vcc general work | Permit status: Permit expired | Completion date: November 11, 2014 | Expiration date: September 27, 2013 | Current use: Business use | Permit id: 13-09412-Vcgen
2013/03/27095541 Royal St [galerie Dart Francais], New Orleans, La
To repair stuccoed masonry as needed to match existing on second-story of both royal & toulouse elevations using the following vcc approved mortar & stucco formula:mortar: no more than 1 part portland cement, 3 parts lime, 9 parts sand, and enough water to form a workable mix. Prepackaged mixes are not permitted, as quality control is not consistent. Stucco: base coat consists of 2 coats, doubled up work of 5 8" total thickness. Proportioned as follows: no greater than 1:12 part portland cement, to 3 parts lime, and 9 parts sand, 6 lbs. Cubic yard hair or fiber, and enough water to form a workable mix. Finish coat is 1 4" in total thickness proportioned as follows: no more than 1 part portland cement, 3 parts lime, 9 parts sand, enough water to form a workable mix. Note: ratio of portland cement not to exceed 1:12. 2016. 04. 05 - permit not picked up.
Date:  June 4, 2014

Permit type: Vcc general work | Permit status: Permit expired due to ina | Completion date: April 5, 2016 | Expiration date: December 5, 2014 | Current use: Business use | Permit id: 14-17601-Vcgen
2014/06/04095541 Royal St [galerie Dart Francais], New Orleans, La
Renewal of permit # 13-09412 to perform the following work: repair masonry cracks as needed with vcc approved mortar stucco mix, using 1 part portland cement, 3 parts lime, 9 parts sand, enough water to form a workable mix repair ground floor millwork including faade vitrine, to match existing conditions repair replace as necessary doors & shutters on the 2nd & 3rd floors street elevations, with the removal of the existing plywood in the openings which is currently in the windows doors of both floors will be removed all repair work shall match existing in color, size, material, detail, profile and exposure to prepare for painting by washing using a low water pressure; sanding (rotary sanders cannot be used); making minor millwork and or masonry repairs as necessary to match existing conditions (masonry mix must be soft with portland cement content not to exceed 1 part to 12); and to paint as follows to match existing:o wallsbay gray, flat or satin finisho wooden elements including door
Date:  February 14, 2014

Permit type: Vcc general work | Permit status: Permit issued | Expiration date: August 17, 2014 | Current use: Business use | Permit id: 14-05170-Vcgen
2014/02/14095541 Royal St [galerie Dart Francais], New Orleans, La
This is a renewal of vcc permit #11-0535to do the following work as necessary: remove deteriorated floor boards, stringers, and fascia boards install new 3"x4" beaded stringers, 5 4x4 s2s t&g floorboards, and 7 8" fascia with " bead, all as per vcc standard detail sheet no. 18 (attached) all repair replacement work shall match existing in color, size, material, detail, profile and exposure prime & paint to match existing color (off-white)
Date:  August 8, 2012

Permit type: Vcc general work | Permit status: Permit expired | Completion date: November 26, 2014 | Expiration date: February 8, 2013 | Current use: Business use | Permit id: 12-21504-Vcgen